Automatic Chlorine Dosing System with Installation – Cyprus
1.500,00 €
- ✅ Italian Etatron Engineering: Professional digital dosing technology from an established Italian manufacturer.
- ✅ Automatic Proportional Dosing: Precisely controlled chemical injection that responds to water consumption through a pulse-output water meter.
- ✅ Complete Treatment Package: Includes the Etatron dosing pump, pulse water meter, 100 L chemical tank and treatment chemical.
- ✅ Professional-Grade Components: Digital dosing control and chemical-resistant pump components designed for demanding water-treatment applications.
- ✅ Professional Installation Included: Supplied and installed by WaterFilterNet across Cyprus, subject to site suitability.
Automatic Chlorine Dosing System — Complete Installation
A controlled chemical dosing system should respond to the amount of water being used. WaterFilterNet’s installed package combines a digital Etatron dosing pump, a pulse-output water meter, a chemical storage tank and the specified treatment chemical.
The system is intended for suitable private and commercial water-treatment installations where chemical injection needs to follow water consumption. Professional installation is included, with site suitability confirmed before the order is accepted.
How does automatic proportional dosing work?
The water meter sends electrical pulses as water passes through it. The dosing pump uses those signals and its programmed settings to deliver a controlled quantity of treatment solution. The dose follows measured water consumption rather than relying only on a fixed operating schedule.
Everything Included in the Package
The following four components are supplied together with professional installation.
| Included item | Specification |
|---|---|
| Digital dosing pump | Etatron DLX-VFT/MBB 05-07, 5 L/h at 7 bar |
| Pulse water meter | 1-inch threaded meter, 1 impulse per litre, maximum 30°C |
| Chemical storage tank | 100-litre polyethylene tank |
| Treatment chemical | CHLORILIQ D500, one 24 kg pack |
| Installation | Professional installation of the specified package at a suitable site |
The chemical is supplied as a 24 kg pack, not as a stated volume in litres. Any additional site modifications, treatment equipment or work outside the specified package will be assessed separately.
How the System Operates
1. Water flow is measured
The pulse meter registers water passing through the pipe and produces a signal for each litre.
2. The pump responds
The Etatron controller interprets incoming pulses according to the selected dosing mode and settings.
3. Chemical is injected
The pump draws compatible solution from the storage tank and delivers it to the water line through the dosing arrangement.
The dosing settings must be established for the specific water supply, chemical concentration and treatment objective. Flow-proportional operation does not independently measure residual chlorine or confirm treated-water quality.
Where Can This System Be Used?
Potential applications include well and borehole water treatment, private water supplies, commercial premises and water storage or distribution systems requiring controlled chemical injection.
The correct treatment design depends on the water source and intended use. Some installations may require filtration, additional disinfection equipment, contact time, monitoring or other measures beyond the dosing package.
Technical Specifications
| Specification | Details |
|---|---|
| Pump manufacturer | Etatron D.S. |
| Pump model | DLX-VFT/MBB 05-07 |
| Rated pump capacity | 5 L/h at 7 bar |
| Control | Manual and external pulse dosing modes |
| Pump head material | PVDF |
| Meter connection | 1-inch threaded |
| Meter pulse rate | 1 impulse/litre |
| Meter temperature limit | 30°C maximum |
| Storage tank | 100 L polyethylene |
| Supplied chemical | CHLORILIQ D500, 24 kg |
| Installation coverage | Across Cyprus, subject to site assessment |
Installation and Site Assessment
WaterFilterNet provides professional installation across Cyprus. Before confirming the job, we assess the water source, pipework, operating conditions, installation space and the intended treatment application.
For a successful installation, the pump, water meter and chemical storage arrangement must be suitable for the actual site. Additional pipework, electrical work, testing, monitoring or treatment stages may require a separate quotation.
Important treatment and safety information
Chemical selection, concentration, compatibility, handling and dosing must follow the applicable supplier documentation and site requirements. For disinfection applications, adequate contact time and residual testing may be necessary. Installing a dosing pump does not by itself guarantee that water is safe to drink.
Monitoring and Maintenance
Regular inspection helps maintain dependable dosing. The pump, chemical level, suction and injection components, pulse signals and delivered treatment dose should be checked at intervals appropriate to the installation.
Where the system is used for disinfection, treated-water testing and residual monitoring are essential parts of an appropriate operating plan. The exact maintenance schedule is determined by the water source and operating conditions.
Frequently Asked Questions
Can this system be installed on a private well?
Potentially, yes. The source water, required treatment and installation conditions must first be assessed.
Does the pump change its dosing when water consumption changes?
Yes, when correctly configured for proportional operation. The pump responds to pulses from the included water meter.
Does the system measure chlorine residual automatically?
No. Residual measurement requires separate testing or suitable monitoring equipment.
Can I order the equipment without installation?
This listing is for the complete installed package. Contact WaterFilterNet if you require an equipment-only quotation.
What happens if my property needs extra pipework?
Any additional work outside the specified installation is assessed and quoted before proceeding.
Will the system make untreated well water safe to drink?
Not automatically. Drinking-water suitability depends on the complete treatment design and verified water-quality results.
Related Water Treatment Services
If your installation involves an existing water storage tank, you may also need a separate water tank cleaning and disinfection service. Cleaning an existing tank is different from installing an ongoing chemical dosing system.
For more information about treatment chemistry, see our guide to chlorine and chlorine dioxide. The appropriate chemical must be selected for the specific application.
Discuss Your Installation with WaterFilterNet
Tell us about your water source and installation requirements. We will help determine whether this package is suitable for your property.